Cat. 6 U/FTP Outdoor Cable

Standards:

  • ANSI/TIA 568.2-D:2018
  • ISO/IEC 11801-1 Class E:2017
  • IEC61156-5:2012 (Edition 2.0)
  • CENELEC EN 50173-1:2018
  • CENELEC EN 50288-5-1:2011
  • RoHS compliant (EU Directive 2011/65/EC)

Application:

  • 1000BASE-TX, 1000BASE-T and lower protocol
  • Campus backbone for CCTV System
  • Outside plant applications

Сonfiguration:

Conductor Material Bare Copper
Construction 23 AWG
Insulation Material PE
Diameter 1.35 ± 0.10mm
Pair shielding Material Individual Al/Pet foil (metal outside)
Drain Wire Material/Size Tinned Copper / 0,4 mm
Sheath Material UV-stabilized PE, thickness 0,6 mm
Size Nominal diameter 6,85 mm

Electrical Performance

Dielectric Strength of Insulation 1200 V dc or 850 V ac / 2 seconds
Insulation Resistance Test Min. 5000 MΩ/m
Conductor Resistance Max.9.38 Ω/100m at 20℃
Resistance Unbalance Max. 2%
Capacitance Unbalance Max. 160 pF/100m
Mutual Capacitance Max. 5600 pF/100m
Impedance 1~100MHz 100Ω ± 15%
100~250MHz 100Ω ± 22%
Attenuation & Near End Cross Talk Frequency Max. Attenuation NEXT PSNEXT
(MHz) (dB/100 meters) (dB), Min. (dB), Min.
1MHz 2.0* 74.3* 72.3*
4MHz 3.8* 65.3* 63.3*
10MHz 6.0* 59.3* 57.3*
16MHz 7.6* 56.2* 54.2*
20MHz 8.5* 54.8* 52.8*
31.25MHz 10.7* 51.9* 49.9*
62.5MHz 15.4* 47.4* 45.4*
100MHz 19.8* 44.3* 42.3*
200MHz 29.0* 39.8* 37.8*
250MHz 32.8* 38.3* 36.3*
The asterisked (*) value are for information only. The minimum Next coupling loss for any pair combination at room temperature is to be greater than the value determined using the formula:

NEXT(f MHZ)NEXT(0.772)-15LOG10(f MHZ/0.772)dB

Ordering information

Part No. 206646122
Description Cat.6 U/FTP outdoor installation cable, PE, black
Packing 305m / reel
X