Cat. 5e F/UTP Outdoor Installation Cable

Standards:

  • ANSI/TIA-568.2-D:2018
  • ISO/IEC 11801-1:2017
  • CENELEC EN 50288-11-1:2012
  • IEC 61156-5:2012(Edition 2.0)
  • EN50173-1:2011
  • RoHS compliant (EU Directive 2011/65/EC

Application:

  • 1000BASE-T Gigabit Ethernet,
  • 100BASE-TX Fast Ethernet,
  • 10BASE-T Ethernet,
  • Campus backbone for CCTV System
  • Outside plant applications
  • Voice

Construction & Physical Character

ConductorMaterial/ SizeBare Copper/ 24 AWG
InsulationMaterialForm-skin, PE
Diameter1.055±0.10 mm
ShieldAl-Mylar type / Mylar typeInsulation on outside surface
Drain wireMaterial / SizeTinned copper / 26AWG
SheathMaterialLDPE/ Black
Diameter6.0±0.4 mm
Operation Temperature-40°C to +60°C

Electrical Performance

Dielectric Strength of Insulation1200 V dc or 850 V ac / 2 seconds
Insulation Resistance TestMin. 5000 MΩ/m
Conductor ResistanceMax.9.38 Ω/100m at 20℃
Resistance UnbalanceMax. 2%
Capacitance UnbalanceMax. 160 pF/100m
Mutual CapacitanceMax. 5600 pF/100m
Impedance1~100MHz100Ω ± 15%
Key Electrical Attributes

Frequency

(MHz)

Max. Attenuation

(dB/100 meters).

NEXT

(dB), Min.

PSNEXT

(dB), Min.

1MHz2.0*65.3*62.3*
4MHz4.1*56.3*53.3*
10MHz6.5*50.3*47.3*
16MHz8.2*47.2*44.2*
20MHz9.3*45.8*42.8*
31.25MHz10.7*42.9*39.9*
62.5MHz17.0*38.4*35.4*
100MHz22.0*35.3*32.3*

The asterisked (*) value are for information only. The minimum Next coupling loss for any pair combination at room temperature is to be greater than the value determined using the

formula:NEXT(f MHZ)≧ NEXT(0.772)-15LOG10(f MHZ/0.772)dB

Category 5e F/UTP Outdoor 

PART NO.DESCRIPTIONPACKING SIZE
725243122Category 5e F/UTP Outdoor Installation Cable, PE, Black, 305m/reel40(O.D.) 21(H) cm